บริษัท ทาคาโอะ เอเชีย จำกัด
โทร 061-703-5369 คุณณัฐธิดา, 063-669-2654 คุณศรันย์รุณี, 090-656-9946 พิมพ์ณิดา, 065-940-4254 ณัฐฐินันท์, 061-542-5890 ออฟฟิศ
  • th

Mitsubishi plc รุ่น FX2N-48MR-UA1/UL


Mitsubishi plc รุ่น FX2N-48MR-UA1/UL

รายละเอียดสินค้า

Ambient temperature : 0 ~ 55 ℃ ・ ・ ・ Operating, -20 ~ 70 ℃ ・ ・ ・ Storage

Relative humidity : 35% to 85% (with no condensation): Operating

Vibration resistance

When mounting DIN rail

Frequency: 10-57Hz

Half amplitude: 0.035 mm X, Y, Z each direction 10 times (total each 80 minutes) criteria, according to IEC61131-2

Frequency: 57-150Hz

Acceleration: 4.9 m / s 2 X, Y, Z each direction 10 times (total each 80 minutes) criteria, according to IEC61131-2

Direct mounting

Frequency: 10-57Hz

Half amplitude: 0.075 mm X, Y, Z each direction 10 times (total each 80 minutes) criteria, according to IEC61131-2

Frequency: 57-150Hz

Acceleration: 9.8m / s 2 10 times in each of the X, Y, and Z directions (total of 80 minutes each) Judgment criteria are based on IEC61131-2

Noise resistance : Using a noise simulator with a noise voltage of 1,000 Vp-p, a noise width of 1 μs, a rise of 1 ns, and a period of 30 to 100 Hz

Withstand voltage : When performing a withstand voltage test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (AC power supply) and ground terminal: AC1.5kV for 1 minute Between input terminal (AC100V) and ground terminal: AC1.5kV for 1 minute Between output terminal (relay) and ground terminal: AC1.5kV for 1 minute

Insulation resistance : When performing an insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (AC power supply) and ground terminal: 5 MΩ or more with DC500V insulation resistance meter Between input terminal (AC100V) and ground terminal: 5MΩ or more with DC500V insulation resistance meter Between output terminal (relay) and ground terminal: DC500V insulation resistance 5MΩ or more in total

Ground : Class D grounding (Grounding resistance: 100Ω or less) Use a dedicated or shared ground for grounding.

Usage atmosphere : There is no corrosive or flammable gas, and the conductive dust (dust) is not severe.

Usage altitude : Cannot be used in an environment pressurized to 2000m or less and atmospheric pressure. There is a possibility of failure.

ราคา:
0.00 THB
หมวดหมู่:
A Series PLC
ปรับปรุงล่าสุด:
30 ตุลาคม 2019
Mitsubishi plc รุ่น FX2N-48MR-UA1/UL บริษัท ทาคาโอะ เอเชีย จำกัด
สอบถาม
สินค้าที่เกี่ยวข้อง
Mitsubishi AC servo drive รุ่น MDS-B-V2-3510

Description : MDS-B-V2-3510 is a Drives-AC Servo produced by Mitsubishi

สอบถาม
แบตเตอรี่ PLC OMRON 3G2A9-BAT08

แบตเตอรี่ PLC รุ่น 3G2A9-BAT08

สอบถาม
แบตเตอรี่ลิเธียม TOSHIBA

แบตเตอรี่ลิเธียม TOSHIBA

สอบถาม
แบตเตอรี่ PLC ALLEN BRADLEY 1756-BATA

แบตเตอรี่ PLC รุ่น 1756-BATA

สอบถาม
Omron Photoelectric switch รุ่น E3ZG-D61

Omron Photoelectric switch รุ่น E3ZG-D61

สอบถาม
Omron proximity switch รุ่น E3Z-T61

Omron proximity switch รุ่น E3Z-T61

สอบถาม
//updateEventProduct(id)